Mettler Toledo BBK462 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Küchenwaage Mettler Toledo BBK462 herunter. Mettler Toledo BBK462 User manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - METTLER TOLEDO

User manual METTLER TOLEDO Compact scales BBA462 / BBK462 123456789.0a b c- , / & d e fj k lm n og h it u vw x y zp q r s+ ...

Seite 2

Chapter 1: Setting up the scale METTLER TOLEDO BBA462 / BBK462 10 In conformance with the European Directive 2002/96 EC on Waste Electrical

Seite 3 - Rear of Scale

Subject to technical changes. Printed on 100% chlorine-free paper. For the sake of our environment. © M

Seite 4

METTLER TOLEDO BBA462 / BBK462 Chapter 1: Setting up the scale 11 Major changes in geographical location: The manufacturer adjusts each scale to t

Seite 5

Chapter 2: Basic functions METTLER TOLEDO BBA462 / BBK462 12 2 Basic functions This Chapter describes how to switch the scale on and off, zero and

Seite 6

METTLER TOLEDO BBA462 / BBK462 Chapter 2: Basic functions 13 2.2 Setting date and time Time can be set in 24 hours or 12 hours format, and the da

Seite 7

Chapter 2: Basic functions METTLER TOLEDO BBA462 / BBK462 14 2.3 Language settings Language can be set into US English, English, German, French, Sp

Seite 8

METTLER TOLEDO BBA462 / BBK462 Chapter 2: Basic functions 15 The bar graph at the top of the display shows how much of the weighing range is be

Seite 9 - 1 Setting up the scale

Chapter 2: Basic functions METTLER TOLEDO BBA462 / BBK462 16 The zero display and the “Net” (net weight) symbol appear. Note: If the automatic tare

Seite 10

METTLER TOLEDO BBA462 / BBK462 Chapter 2: Basic functions 17 2.5.3 Determining the gross and net weights Place the empty weighing container

Seite 11

Chapter 3: Enhanced functions METTLER TOLEDO BBA462 / BBK462 18 3 Enhanced functions This Chapter describes the BBA462 / BBK462 features that simp

Seite 12 - 2 Basic functions

METTLER TOLEDO BBA462 / BBK462 Chapter 3: Enhanced functions 19 3.2 Database The following describes the operations for working with the article

Seite 13

Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use according to this Operating Manual and regular calibration and

Seite 14 - key again

Chapter 3: Enhanced functions METTLER TOLEDO BBA462 / BBK462 20 Press «Delete» to remove the current article from the database. You will be asked t

Seite 15

METTLER TOLEDO BBA462 / BBK462 Chapter 3: Enhanced functions 21 Identification / ID1 and ID2 Additional identification parameters for the article

Seite 16 - softkey

Chapter 3: Enhanced functions METTLER TOLEDO BBA462 / BBK462 22 Example: In order to have the wearing down of the filling machine reflected, the alr

Seite 17

METTLER TOLEDO BBA462 / BBK462 Chapter 3: Enhanced functions 23 - Accumulation total pcs. The total number of pieces for the Accumulation applica

Seite 18 - 3 Enhanced functions

Chapter 3: Enhanced functions METTLER TOLEDO BBA462 / BBK462 24 3.2.4 Save As Article function In the course of working with BBA462 / BBK462, you ma

Seite 19 - » key

METTLER TOLEDO BBA462 / BBK462 Chapter 3: Enhanced functions 25 3.4 SmartManager To make working with the article database even easier, as well a

Seite 20 - Defining an article

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 26 4 Application Your scale has a number of powerful application functions that can be activa

Seite 21

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 27 Press the «Smpl 10» key. Note: If a different number of pieces has been placed on the s

Seite 22

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 28 Press the «OK» key. The scale has established a known reference weight and is now ready

Seite 23

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 29 Press the «Smpl 10» or «Smpl n» keys to determine the reference, as described in the prev

Seite 24 - Save As Article function

OverviewRear of ScaleScale specifications (example)KeypadMax1: 3kg Min1: 20g e1: 1g d1: 1gMax2 6kg Min2: 40g e2 2g d2: 2g18 19 20 21Display2829303132

Seite 25 - 3.5 FlashLoader

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 30 10 samples were placed on the scale and «Smpl 10» was pressed. BBA462 / BBK462 calculate

Seite 26 - 4 Application

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 31 4.6 Piece counting with 2-scale systems You can hook up your BBA462 / BBK462 scale to a

Seite 27

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 32 Note: You can specify in Vision Setup "APPLICATION Æ Counting Æ Total Pieces",

Seite 28

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 33 Press the «+» softkey to add the current number of pieces to the total, or the «-» so

Seite 29

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 34 4.8 Accumulation to target The „accumulation to target“ function allows accumulation up

Seite 30

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 35 4.9 Filling The filling application simplifies weighing of small parts (e.g. liquid or p

Seite 31

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 36 Press the «+/-» softkey. In this example, Target (target weight), + Tol (positive tolera

Seite 32

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 37 Press the «SetUnit» softkey and enter the abbreviation of the custom unit. Confirm by pr

Seite 33

Chapter 4: Application METTLER TOLEDO BBA462 / BBK462 38 Press the «HighRes» softkey in order to display the net weight at a higher resolution. Note

Seite 34

METTLER TOLEDO BBA462 / BBK462 Chapter 4: Application 39 Press the «Search» softkey in order to reach the search mask of the alibi memory. With th

Seite 35

Overview 1 Display 2 On/Off key 3 Tare key 4 Zero key 5 Enter key 6 Command softkeys 7 Keypad 8 Adjustable feet 9 Weighing pan 9a: wind pr

Seite 36

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 40 5 Vision setup Vision Setup can be used to change the settings of the scale and to activa

Seite 37

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 41 This key selects the first item on the next “page” of the menu. If all the items for the

Seite 38 - 4.13 Alibi memory

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 42 5.3 Menu overview 5.3.1 Scale ScaleScale 1Scale 2CalibrationStart?- 0 -xxx gxxx g- done

Seite 39

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 43 5.3.2 Application ACounting Database Identification AccumulationPrintoutCom 1..3Lot Pri

Seite 40 - 5 Vision setup

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 44 Applications continued…. AFilling/Checkweighing Alibi Memory Softkey Config Info/Help Res

Seite 41

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 45 5.3.3 Terminal TerminalWeight DisplayInvert Date TimeBeepContrast010YesNosmallbigEUDate

Seite 42 - 5.3 Menu overview

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 46 5.3.4 Communications CKeyboardUS Internat.UKFrenchSwiss FrenchBelgian FrenchGermanGerman

Seite 43 - Application

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 47 Communications continued… ModePrinterAuto PrintCont WeightDialog2nd DisplayReference S

Seite 44 - Applications continued

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 48 Communications continued… Line 1 Line 23FontStandardBoldBigBig & BoldBC Code39BC EAN

Seite 45 - Terminal

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 49 5.3.5 Diagnostics Keyboard TestDiagnosticsDisplay TestSNR 2List 1 List 2 List MemoryWor

Seite 46 - Communications

METTLER TOLEDO BBA462 / BBK462 Table of Contents 5 1 Setting up the scale ...

Seite 47 - Communications continued…

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 50 5.4.1 Adjust/calibrate (SCALE Æ Calibration) This function enables the scale to be adjust

Seite 48

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 51 5.4.3 Tare settings (SCALE Æ Tare) This function allows the user to configure all the

Seite 49 - Diagnostics

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 52 Press «Edit» to switch the automatic save switch function on or off. 5.4.6 Adaptation t

Seite 50

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 53 5.4.7 Automatic adjustment (SCALE Æ FACT) FACT function allows the user temperature or

Seite 51

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 54 - Press «» to go to the Min Weigh settings. Press «Edit» to switch the minimum weight

Seite 52

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 55 5.5.1 Settings for piece counting (APPLICATION Æ Counting) The Sample_X parameter deter

Seite 53

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 56 "Def. User Prompt" function allows the user to define a step-by-step flow pr

Seite 54

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 57 Minimum Sample Weight This setting controls the limits for reference weight determina

Seite 55

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 58 5.5.2 Settings for database (APPLICATION Æ Database) The following illustrates the possib

Seite 56

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 59 Recall - This function allows recalling of an article directly from the database via

Seite 57

Table of Contents METTLER TOLEDO BBA462 / BBK462 6 4.4 Minimum sample weight ...

Seite 58

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 60 5.5.4 Settings for accumulation (APPLICATION Æ Accumulation) These settings define the con

Seite 59

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 61 Manual - Perform the accumulation manually by confirming with the «+» or «-» key. Auto

Seite 60

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 62 Select "on" or "off" for activating/deactivating the alibi memory. Apa

Seite 61

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 63 Multi Tare Show the «MulTare» softkey. With this softkey, it is possible to enter the nu

Seite 62

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 64 Each Info line can be configured to display any of the following information: Not Used

Seite 63

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 65 5.6 Terminal settings for device (TERMINAL Æ Device) This function block allows the use

Seite 64

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 66 Press the «Edit» softkey to go to the Sleep settings menu. The scale will turn itself

Seite 65

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 67 Press the «Edit» softkey to go to the Weight Display settings menu. Default setting is

Seite 66 - to confirm

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 68 Press the «» softkey … … and then press the «Edit» softkey to enter a new password. En

Seite 67

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 69 The screen shows the most important communication settings as a preview. The screen sh

Seite 68 - softkey …

METTLER TOLEDO BBA462 / BBK462 Table of Contents 7 5.5.6 Settings for the (optional) alibi memory -> APPLICATION-> Alibi memory...

Seite 69 - Mode (COMMUNICATIONS Æ Mode)

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 70 In this example, COM1 is set to Dialog (also known as "Host Mode" for MT-SICS co

Seite 70

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 71 BBA462 / BBK462 gives you the possibility to generate up to five different user-defined

Seite 71

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 72 - Press «Edit» to change settings of Baud, Parity or Handshake. Baud: Parity: Handshak

Seite 72

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 73 Choose < Range-, < Tol-, Good, > Tol+, >Range+, Output off or Reset I/0 and

Seite 73

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 74 Choose "IP Address", Subnet Mask", or "Gateway" and press «Edit»

Seite 74

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 75 Digital I/O option The Digital I/O option allows to control the scale via peripheral de

Seite 75

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 76 5.9.7 PS2 Settings (COMMUNICATIONS Æ PS2) This function allows setting up of the periphera

Seite 76

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 77 Choose "Def. Printer" and press the « » to go to the settings of user-defined

Seite 77

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 78 Choose "Font" to change the layout of the printout. (This menu is not available

Seite 78

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 79 The desired template can now be selected. "Standard" as active is the factory

Seite 79

Table of Contents METTLER TOLEDO BBA462 / BBK462 8 6 Other important information ...

Seite 80

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 80 5.10.1 Scale (DIAGNOSTICSÆ Test Scale) Please refer to Chapter 5.3.5 on how to reach the m

Seite 81

METTLER TOLEDO BBA462 / BBK462 Chapter 5: Vision setup 81 5.10.3 Display (DIAGNOSTICSÆ Display Test) Please refer to Chapter 5.3.5 on how to reac

Seite 82

Chapter 5: Vision setup METTLER TOLEDO BBA462 / BBK462 82 5.10.7 List 2 (DIAGNOSTICSÆ List 2) Please refer to Chapter 5.3.5 on how to reach the menu

Seite 83 - Other important information

METTLER TOLEDO BBA462 / BBK462 Chapter 6: Other important information 83 6 Other important information This Chapter gives information on error me

Seite 84

Chapter 6: Other important information METTLER TOLEDO BBA462 / BBK462 84 Reference piece weight too small When defining the reference weight, the sc

Seite 85 - 6.2 Sample reports

METTLER TOLEDO BBA462 / BBK462 Chapter 6: Other important information 85 6.2 Sample reports Weigh mode (c) Mettler-Toledo GmbH http://www.m

Seite 86

Chapter 6: Other important information METTLER TOLEDO BBA462 / BBK462 86 6.3 Variable and control sequences in entering a "Free Text" Des

Seite 87 - 6.4 Cleaning instructions

METTLER TOLEDO BBA462 / BBK462 Chapter 6: Other important information 87 Accumulation max n $ACM Returns value „max n“ from the Accumu- lation

Seite 88

Chapter 7: Technical data, interfaces and accessories METTLER TOLEDO BBA462 / BBK462 88 7 Technical data, interfaces and accessories In this chapte

Seite 89

METTLER TOLEDO BBA462 / BBK462 Chapter 7: Technical data, interfaces and accessories 89 Ambient conditions  Use  Altitude  Temperature ran

Seite 90 - 7.2 Dimensions

METTLER TOLEDO BBA462 / BBK462 Chapter 1: Setting up the scale 9 1 Setting up the scale Please read through these operating instructions careful

Seite 91 - 7.4 Accessories

Chapter 7: Technical data, interfaces and accessories METTLER TOLEDO BBA462 / BBK462 90 7.2 Dimensions A B C D E F G H I K L P1) 13.19 10

Seite 92 - SICS Command set

METTLER TOLEDO BBA462 / BBK462 Chapter 7: Technical data, interfaces and accessories 91 Technical data for 'Analog' option: A/D-Converte

Seite 93 - TOLEDO Continuous commands

Chapter 7: Technical data, interfaces and accessories METTLER TOLEDO BBA462 / BBK462 92 7.5 Interface commands Your scale can be configured and ope

Seite 94

METTLER TOLEDO BBA462 / BBK462 Chapter 7: Technical data, interfaces and accessories 93 SICS Manual (Order Number 22 011 459 or at www.mt.com) or b

Seite 95 - 7.8 Compliances

Chapter 7: Technical data, interfaces and accessories METTLER TOLEDO BBA462 / BBK462 94 Status word A Status Bit Function Selection 6 5 4 3 2 1 0 De

Seite 96 - 8 Appendix

METTLER TOLEDO BBA462 / BBK462 Chapter 7: Technical data, interfaces and accessories 95 7.7 Information for verified scales Important notice for

Seite 97

Chapter 8: Appendix METTLER TOLEDO BBA462 / BBK462 96 8 Appendix 8.1 Safety checks The compact scales of the series BBA462 / BBK462 have been ch

Seite 98

METTLER TOLEDO BBA462 / BBK462 Index 97 2 2nd display ... 69 2-scale ...

Seite 99

Index METTLER TOLEDO BBA462 / BBK462 98 L language.....14, 65 M manual reference optimization...

Kommentare zu diesen Handbüchern