Seite 1 - AM/PM Balances

Operating instructionsMETTLER TOLEDOAM/PM Balances_;_;_;

Seite 2

10Switch on display (▼ Display changes automatically)Display switched off (standby)Briefly press controll bar; all display segments light up briefly(a

Seite 3

11Simple weighingCaution: Before the balance is used for the first time, it must be calibrated (see «Calibration» in section «Menu»).Taring (▼ display

Seite 4 - Select the proper location

12Simple operation with a control barSwitching on/off, calibrating, configuring: All of these operations can be initiated with the control bar. You ca

Seite 5 - …and now, level the balance

13Introducing the symbolsTry to familiarize yourself with the key symbols with the aid of the following example. Switch on the display and remove weig

Seite 6 - Preparation

14MenuWe distinguish between two levels of software. The first, simpler level, we call the Menu. It can be activated by pressing and holding the contr

Seite 7

15Before the balance is used for the first time, it must be calibrated (to take the acceleration due to gravity into account).Caution: To obtain accur

Seite 8 - Operation

16AccessYour balance is now operating in the animal weighing mode, e.g.movements of a live animal do not influence the display. The measure-ment value

Seite 9 - balances…

17Adjustments Weighing environment RemarksWhit this setting your balance operates very fast (short weighing cycle),but the balance is relatively sensi

Seite 10 - Switch off display

18Special requirements need special settings within the configuration fileConfiguringYour balance has been factory-set to a standard configuration, i.

Seite 11 - Simple weighing

19Unit selection, applications, etc.Selection of basic unitSelection of second unit and applicationsPrint/transfer command / Starting animal weighing

Seite 12 - Note these symbols…

2Thank you very much for the confidence you have shown in our products by choosing a METTLER TOLEDO precision or analytical balance. Toobtain complete

Seite 13 - Introducing the symbols

20AccessStart from standby, i.e. display switched off.Now, press control bar and release only when displayshows –Conf.–.Display now automatically chan

Seite 14 - A clear Menu

21gHave you found the setting –Unit 1–? If not, switch off the display by lifting the control bar.Then restart by accessing the configuration file. Th

Seite 15 - Calibrate your balance

22AccessStandbySymbolsPresscontrol barbrieflyPress and holdcontrol baruntil required display appearsDisplay changes automaticallyConfiguringStandard s

Seite 16

23Standard setting Yes / NoFor resetting your balance to standard configuration, select sector –reset–. Now press control bar until –yes– isdisplayed.

Seite 17

24AccessStandbySymbolsPresscontrol barbrieflyPress and holdcontrol baruntil required display appearsDisplay changes automaticallyConfiguringStandard s

Seite 18 - Configuring

25Selection of display sequences (Readability)Example for 0.1-g balances:Step (d) 1 2 5 10 20 50 100Display (g)ConfiguringSettingsAutomatic stability

Seite 19

26ImportantReturn to weighing mode always with control bar depressed until zero indication.If you do not press control bar for 40 sec, the balance wil

Seite 20

27Basic weighing unitIn addition to the weight unit g, the following weight units can be selected for weighing:gram kilogram pound ounces troy ounces

Seite 21

28Adaptation to external equipmentSymbolsConfiguringAccessStandbyGeneral informationAll METTLER TOLEDO precision or analytical balances are factory-eq

Seite 22

29ConfiguringSetting optionsDatenübertragungsmodusThe next possible stable value is transferred after initiation of print/transfer command (after rele

Seite 23

3PagePreparation Choosing the location 4Mounting the weighing pan / levelling the balance 5Installing the draft shield 6Operation Control elements / c

Seite 24

30After having completed your configuration, you can protect your settings against inadvertent changes. Proceed as follows:To protect the program cass

Seite 25

31In the aperture of the program cas-sette 2, the shorting jumper 24 isnow visible. It can be lifted off fromthe contact pins (e.g. with a smallpencil

Seite 26

32ApplicationsSymbolsCounting in or out of a container, percent formula weighing of powders or liquids, plus/minus checks of fill quantities, weighing

Seite 27

33ConfigurationStandbyIn the configuration file, select the setting–Unit 1– in the –Unit– sector: The standardsetting has the basic unit gram (g). If

Seite 28

34PCSPiece counting (fixed reference number – 10 pieces, 1 item at least 1/4 digit)ConfigurationApplicationsStandbySelect –Unit 2– in sector –Unit– of

Seite 29

35Switch piece count/weight readoutReturn to weighing modeSelect piece countingCounting out of a containerPlace filled container onbalance, tareRemove

Seite 30

36Plus/minus and percent weighing (tolerance limit ± 2,5%, 100 % = target weight, min. weight = 100 digit)CheckweighingConfigurationStandbyNow changes

Seite 31

37Switch percent weighing/weighing modeFine weighing-inAdd weighing samplegradually; the fine indicatormoves upward (fine indica-tor position 12 o&apo

Seite 32 - Applications

38ConfigurationThe various displays have the following meaningsSee also section «Operation».Set weighing process adapter 31b to«Animal weighing»Use vi

Seite 33 - Switching weight unit

39Initiate print/transfer commandConfigurationStandbySelect –Prt off– in sector –Unit– of configurationfile.Now changes this setting to –Prt on– .The

Seite 34

4PreparationSelect the proper locationFor best results choose a suitable location for your balance.A firm, vibration-free location as horizontal as po

Seite 35

40What if…Correction- Check power system;- Switch on scale- Connect power cable- Switch scale off/on, or pull out/plug in powercable- Correct voltage

Seite 36

41DisplayDefinitionIncorrect resultUnstable when taring,calibrating or settingreferenceTaring in overload orunderload conditionReference insufficientE

Seite 37

42211720221110211110402220MiscellaneousMake sure the power cable 20 is disconnected. With the power cableconnected, the inside of the balance is live

Seite 38 - Animal weighing

434111101612/15111016A soiled protective cover can be exchanged as follows: Lift off weighingpan 10 and pan holder 11. For balances with round weighi

Seite 39 - Print/transfer command

44You can't know all the wordsCalibrating Adapting the balance to a reference weightConfiguration cycle A run through the configuration fileConfi

Seite 40 - What if…

45AM50 AM100 PM100 PM200 PM400 PM1200 PM5003 PM480 PM2500Comparator DeltaRange DeltaRangeReadability 0.1 mg 0.1 mg 0.001 g 0.001 g 0.001 g 0.001 g 0.0

Seite 41

46Technical dataPM300 PM600 PM2000 PM4000 PM6100 PM4800 PM3000 PM6000 PM6DeltaRangeReadability 0.01 g 0.01 g 0.01 g 0.01 g 0.01 g 0.1 g 0.1 g 0.1 g 1

Seite 42

Printed on 100 % chlorine-free Paper, for the sake of our environment.

Seite 43

© Mettler-Toledo GmbH 1999 702395C Printed in Switzerland 9910/2.12Mettler-Toledo GmbH, Laboratory & Weighing Technologies, CH-8606 Greif

Seite 44 - Miscellaneous

5PM balances with weighing panPlace pan support 11 and weighingpan 10 on tapered pin 17; connectpower cable 20.PM balances with weighing platformInsta

Seite 45 - Technical data

6To ensure that the weighing results are not influenced by the drafts (particularly for sensitive measuring ranges) we recommend the installationof a

Seite 46

7AM balancesMount glass draft shield 13 on scalerotated by 45°. Note that tapered pin17 must be visible through bottomhole 27. Now rotate glass draft

Seite 47

8Operation1 Control bar2 Program cassette3 Cover4 Connector for data interface5 Connector for METTLER TOLEDO GM instruments6 Fuse holder (with spare f

Seite 48 - Thank you

9This dynamic graphic indicator with 60 radial segments is incorporated in all balance models. METTLER DeltaTrac shows you a graphicrepresentation of

Kommentare zu diesen Handbüchern