METTLER TOLEDO Weigh Module Systems Handbook
(12/99)3-8
What Kind of Accuracy Can
You Expect in the Real
World?
A scale is only as accurate as its load cells. The best you can expect from a scale is that
it will approach the performance rating of the load cells alone. Here are typical
performance ratings for a quality load cell:
± 0.01% R.C. non-linearity
± 0.02% R.C. hysteresis
± 0.03% R.C. combined error
Combined error for a sample load cell is shown in Figure 3-5 as an error band from
zero to full capacity. All weight readings should fall within this error band. Under ideal
conditions, a scale system’s accuracy can approach the accuracy of the load cells
alone (0.03% of system capacity). But in the real world, accuracy can be reduced by
environmental and installation factors such as live-to-dead connections, piping, and the
structural integrity of tank supports.
Actual system accuracy can be determined only by testing and validation after the
system has been installed. Following the guidelines in this handbook will help you
provide the most accurate weighing system possible for your application.